TM 11-6625-2398-15-2
Accuracy over the band ............2.5 db max., including in-
1-5. Technical Characteristics
.............................................. sertion loss.
a. Hybrid Attenuator Assembly CN-1322/TPM-24
Insertion loss ............................0.5 db, max.
(V).
VSWR.......................................1.5: 1 max.
(1) Hybrid junction.
The following is a
Power rating .............................6 kilowatts peak, 10 watts av-
summary of the characteristics of the hybrid junction:
.............................................. erage.
Impedance ............................... 50 ohms, nominal
b. Interconnecting Box J-3113/TPM-24(V).
Frequency range...................... 1000-1200 MHz
Nominal coupling ..................... 3, +0.3, -0 db
Input power...............................115 vac 10%, 60 Hz 5%
Max. Deviation ........................ 0.25 dB
..............................................115 vac 10%, 400 Hz 5%
Max. VSWR ............................ 1.3: 1
Azimuth speed control ..............0 to 25 rpm
Min. Isolation
20 db between sum and
Resolver output ........................26 vac 10%, 4 kHz 5
difference.
Resolver electrical error ...........3 minutes of arc
Power rating............................. 5 kilowatts peak, 50 watts
Resolver null voltage ................20 mv total,
............................................. average.
..............................................15 mv fundamental.
Synchro output .........................90 vac 10%
(2) Attenuator. The following is a summary of
Synchro electrical error ............6 minutes of arc
the characteristics of the attenuator:
Synchro null voltage .................60.0 mv total,
..............................................30.0 mv fundamental.
Impedance ............................... 50 ohms, nominal
Frequency range...................... 1000-1200 MHz
1-6. Common Names
A list of nomenclature and common name assignment
Calibration accuracy at ............ 0-10 db 0.35 db, 10-20 db
for the test facilities set is given below.
1090 MHz (not including ...... 0.50 db, 20-25 db 0.60
insertion loss). ...................... db
Common name
Nomenclature
Test facilities set ....................................................................................... Test Facilities Set AN/TPM-24 (V) 2 Interconnecting Group ON-
Group 1 ..................................................................................................... 119/TPM-24 (V).
Transit case 1A1 ....................................................................................... Case Accessories CY-7308/TPM-24 (V).
Shorting plug 1A1AT1 ............................................................................... Dummy Connector, Plug MX-9355/TPM-24 (V).
Dummy load 1A1AT2/1A1AT3
Interface adapter unit 1A1A1..................................................................... Interconnecting Box J-3113/TPM-24 (V).
PC board extractor 1A1A2......................................................................... Extractor, Circuit Board.
Extender card 1A1A3/1A1A4..................................................................... Extender Card, Electronic Test MX-9356/TPM-24 (V).
Cable kit 1A2 ............................................................................................ Kit, Cable.
Cable 1A2W1 ............................................................................................ Cable Assembly, Power, Electrical CX-12897/TPM-24 (V) (10 ft).
Cable 1A2W2 ............................................................................................ Cable Assembly, Power, Electrical CX-12898/TPM-24 (V) (10 ft).
Cable 1A2W3 ............................................................................................ Cable Assembly, Power, Electrical CX-12899/TPM-24 (V) (6 ft).
Cable 1A2W4/1A2W5 ............................................................................... Cable Assembly, Radio Frequency CG-3750/TPM-24 (V) (2 ft).
Cable 1A2W6/1A2W7 ............................................................................... Cable Assembly, Radio Frequency CG-3750/TPM-24 (V) (20 ft).
Cable 1A2W8 ............................................................................................ Cable Assembly, Special Purpose, Electrical CX-12905/TPM-24 (V) (6
ft).
Cable 1A2W9/1A2W10 ............................................................................. Cable Assembly, Special Purpose, Electrical CX-12906/TPM-24 (V) (6
ft).
Cable 1A2W11 .......................................................................................... Cable Assembly, Special Purpose, Electrical CX-12907/TPM-24 (V) (3
ft).
Cable 1A2W12 .......................................................................................... Cable Assembly, Radio Frequency CG-3751/TPM-24 (V) (8 ft).
Cable kit 1A3............................................................................................. Kit, Cable.
Cable 1A3W1 ............................................................................................ Cable Assembly, Special Purpose, Electrical CX-12901/TPM-24 (V)
(10 ft).
Cable 1A3W2 ............................................................................................ Cable Assembly, Special Purpose, Electrical CX-12908/TPM-24 (V) (6
ft).
Cable 1A3W3 ............................................................................................ Cable Assembly, Special Purpose, Electrical CX-12909/TPM-24 (V) (6
ft).
Cable 1A3W4 ............................................................................................ Cable Assembly, Special Purpose, Electrical CX-12910/TPM-24 (V) (6
ft).
Cable 1A3W5 ............................................................................................ Cable Assembly, Special Purpose, Electrical CX-12911/TPM-24 (V) (6
ft).
Cable kit 1A4............................................................................................. Kit, Cable.
Cable 1A4W1 ............................................................................................ Cable Assembly, Special Purpose, Electrical CX-12902/TPM-24 (V) (6
ft).
Cable 1A4W2 ............................................................................................ Cable Assembly, Radio Frequency CG-3749/TPM-24 (V) (6 ft).
Change 1 1-4