SECTION II MAINTENANCE ALLOCATION CHART
FOR
TEST FACILITIES SET AN/TPM-24(V)2
(1)
(2)
(3)
(4)
(5)
(6)
MAINTENANCE LEVEL
GROUP
MAINT.
TOOLS AND
NUMBER
COMPONENT ASSEMBLY
FUNCTION
C
O
F
H
D
EQUIPMENT REMARKS
010306
CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL
CX-10773/U (1A4W15)
L
CG-3749/TPH-24(V) (1A4W2)
L
CG-3752/TPM-24(V) (1A4W6, 1A4W7, 1A4W8,
L
1A4W9, 1A4W10, 1A4W11, 1A4W12, 1A4W13)
CG-3753/TPM-24(V) (1A4W16)
L
0104
CABLE KIT NO. 4 (1A5)
010401 CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL
CX-1 2900/TPM-24(V) (1AW1)
L
O10402 CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL
CX-12904/TPM-24(V) (1A5W2)
L
0105
CABLE ACCESSORIES CY-7308/TPM-24(V) (1A1)
Inspect
0.1
A
Service
0.2
M
Replace
0.1
17
E
Repair
0.3
17
Repair
0.5
20
010501
BOX, INTERCONNECTING J-3113/TPM-24(V) (1A1A1)
Inspect
0.1
A
Test
0.2
G
Test
0.2
G
Install
0.1
Replace
0.1
Repair
0.5
17
F
01050101 GEAR TRAIN ASSEMBLY (1A1AIA13)
Inspect
0.1
A
Test
0.2
G
Calibrate
0.4
17
E
Install
0.3
17
D
Replace
0.3
17
D
Repair
0.5
17
H
010502
EXTENDER CARD, ELECTRONIC TEST
Inspect
0.1
A
MX-9356/TPM-24(V) (1A1A3, 1A1A4)
Test
0.1
G
Install
0.1
Replace
0.1
17
F
Repair
0.5
17
F
0106
Inspect
0.1
A
MX-9357/TPM-24(V) (1A6)
Install
0.1
Replace
0.1
Repair
0.2
17
F
02
INTERCONNECTING GROUP ON-120/TPM-24(v)(2)
Inspect
0.2
A
Test
0.3
1
B
Test
1.0
1-16
C
Calibrate
1.0
1-16
I
Install
0.2
Replace
0.2
F
Repair
1.0
17-20
F
0201
CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL
BRANCHED CX-12915/TFM-24(V) (21)
L
020101
SWITCH BOX ASSEMBLY (2WA1)
L
0202
CG-3754/TPM-24(V) (2W2, 2W3, 2W4, 2W5, 2W6)
L
0203
CG-3750/TPM-24(V) (2W7, 2W8)
L
0204
CASE, ACCESSORIES CY-7307/TPM-24(V) (2A2)
Inspect
0.1
A
Service
0.2
M
Replace
0.1
17
Repair
0.3
17
F
Repair
0.5
20
Change 2 C-4