TM 11-6625-2398-14-4
SECTION II. MAINTENANCE ALLOCATION CHART
FOR
AN/TPM-24(V)4
(1)
(2)
(3)
(4)
(5)
(6)
TOOLS
GROUP
MAINTENANCE
MAINTENANCE CATEGORY
AND
NUMBER
COMPONENT ASSEMBLY
FUNCTION
C
O
F
H
D
EQUIPMENT REMARKS
05
CABLE ASSEMBLY, POWER ELECTRICAL, (100FT.,
INSPECT
0.1
NONE
A
SPECIAL PURPOSE AC POWER)
TEST
0.1
11
B
SM-D-787809
TEST
0.2
11,12
B,0
(1A1W2)
SERVICE
0.2
19,20
F,G
REPAIR
0.2
11,12,19,21
H
REPLACE
0.1
NONE
06
CABLE ASSEMBLY, RADIO FREQUENCY (6FT.)
INSPECT
0.1
NONE
A
CG-3750/TPM-24(V)
TEST
0.1
11
B
(1A1W3,W4)
TEST
0.2
11,12
B,O
(TOTAL QTY: 2)
CALIBRATE
0.2
2,7,9,10,11
D
19
SERVICE
0.2
19,20
F,G
REPAIR
0.2
2,7,9,10,11
H
12,19,21
REPLACE
0.1
NONE
07
CABLE ASSEMBLY, RADIO FREQUENCY (8FT.,
INSPECT
0.1
NONE
A
SPECIAL PURPOSE, BRANCHED)
TEST
0.2
11
B
SM-D-986522
TEST
0.2
11,12
B,O
(1A1WS)
CALIBRATE
0.2
2,7,9,10,11
D
19
SERVICE
0.2
19,20
F,G
REPAIR
0.3
2,7,9,10,11
H
12,19,21
REPLACE
0.1
NONE
08
CABLE ASSEMBLY, RADIO FREQUENCY (3FT.)
INSPECT
0.1
NONE
A
CG-3754/TPM-24(V)
TEST
0.1
11
B
(1A1W6,W7,W8)
TEST
0.2
11,12
B,O
(TOTAL QTY: 3)
CALIBRATE
0.2
2,7,9,10,11
D
19
SERVICE
0.2
19,20
F,G
REPAIR
0.1
2,7,9,10,11
H
12,19,21
REPLACE
0.1
NONE
09
INSPECT
0.1
NONE
A
SM-D-986535
TEST
0.1
11
B
(1A1W9)
TEST
0.2
11,12
B,O
CALIBRATE
0.2
2,7,9,10,11
D
19
SERVICE
0.2
19,20
F,G
REPAIR
0.2
2,7,9,10,11
H
12,19,21
REPLACE
0.1
NONE
10
INSPECT
0.1
NONE
A
SM-D-986536
TEST
0.1
11
B
(1A1W10)
TEST
0.2
11,12
B,O
CALIBRATE
0.2
2,7,9,10,11
D
12,19
SERVICE
0.2
19,20
F,G
REPAIR
0.2
2,7,9,10,11
H
12,19,21
REPLACE
0.1
NONE
11
CASE ACCESSORIES
INSPECT
0.1
NONE
A
CY-8014/TPM-24(V)
SERVICE
0.1
20
F
(1A1A2)
SERVICE
0.2
19
F,L,S
REPAIR
0.1
V
REPAIR
U
REPLACE
0.1
NONE
DUMMY LOAD, ELECTRICAL (50 OHM TERMINATION)
INSPECT
0.1
NONE
A
DA-558/TPM-24(V)
TEST
0.1
11
B
(1A1A2AT1,AT2)
CALIBRATE
0.2
1,2,5,7,10
C
(TOTAL OTY: 2)
11,19
SERVICE
0.1
20
F
REPLACE
0.1
NONE
T
D-4