TM 11-6625-2398-14-4
SECTION IV. REMARKS
REFERENCE
CODE
REMARKS
A
BY VISUAL INSPECTION
B
C
BY CHECKING VSWR AND ATTENUATION OF ELECTRICAL DUMMY LOADS
D
BY CALIBRATION OF INSERTION LOSS FOR RF CABLES IN ACCORDANCE WITH TB 11-
6625-2398-35
E
BY CALIBRATION OF INSERTION LOSS FOR HYBRID ATTENUATOR SUM/DIFFERENCE
CHANNELS AND CALIBRATION OF HYBRID ATTENUATOR DIAL IN ACCORDANCE WITH TB
11-6625-2398-35
F
BY CLEANING, SUCH THAT ELECTRICAL CONTACTS AND METAL SURFACES ARE FREE OF
DUST, DIRT, AND GREASE
G
BY TAPING MINOR CUTS OF CABLES
H
BY REPAIRING BROKEN AC/DC POWER AND RF CABLE CONNECTORS IN ACCORDANCE
WITH TM 11-6625-2398-14-4
I
BY REPAIRING EXTENDER CARD CONNECTOR CONTACTS IN ACCORDANCE WITH TM 11-
6625-2398-14-4
J
BY REPAIRING HYBRID JUNCTION (SEE REF. CODE XK), AND REPLACEMENT OF
VARIABLE ATTENUATOR, RF CABLES AND PIECE PARTS, IN ACCORDANCE WITH TM 11-
6625-2398-14-4
K
REPAIR HYBRID JUNCTION BY PIECE PART REPLACEMENT
L
BY SERVICING THE DAMAGED SURFACE OF TRANSIT CASE AND ACCESSORY CASE IN
ACCORDANCE WITH TM 11-6625-2398-14-4
M
BY PERFORMING VSWR TEST ON HYBRID ATTENUATOR IN ACCORDANCE WITH TB 11-
6625-2398-35
N
BY PERFORMING INSERTION LOSS TEST ON HYBRID ATTENUATOR IN ACCORDANCE
WITH TB 11-6625-2398-35
O
BY PERFORMING INSULATION BREAKDOWN TEST ON RF CABLES IN ACCORDANCE WITH
TM 11-6625-2398-14-4
P
BY PERFORMING VSWR TEST ON RF CONVERTER
Q
BY PERFORMING FREQUENCY RESPONSE TEST ON RF CONVERTER
R
BY PERFORMING HIGH LEVEL AND LOW LEVEL SENSITIVITY TEST ON RF CONVERTER
S
TOUCH UP PAINTING
T
NON-REPAIRABLE ITEM, REPLACE IF DEFECTIVE
U
FACTORY REPAIRABLE; REPLACEMENT OF HINGES, FASTENER AND HANDLES REQUIRES
WELDING AND REPAINTING
V
BY TIGHTENING LOOSE HANDLE