TM 11-6625-2398-15-2
Step No.
Procedure
Normal indication
Corrective action
a. Check switch 1A1A1S1 and
4
Return RPM control to 0. Set
400-Hz circuit breaker remains on.
GROUP CASE POWER 60-Hz
GROUP CASE POWER in-
associated wiring.
b. Check circuit breaker 1A1A1CB2
circuit breaker to OFF. 400-Hz
dicator lamp lights.
circuit breaker to ON, and
and associated wiring.
GROUP CASE POWER
SELECT switch to 400 Hz.
5
Set POWER 60-Hz circuit breaker to
The 400-Hz circuit breaker remains
Isolate and replace defective part:
a. Circuit breaker 1A1A1A1CB4 or
OFF. 400-Hz circuit breaker to
on. The POWER indicator lamp
lights
associated wiring.
b. Interlock switch 1A1A1S15 or
SELECT switch to 400 Hz.
associated wiring.
c. Switch 1A1A1S4 o associated
wiring.
6
Set GROUP CASE POWER and
POWER switches to OFF.
1A1A1J10-H and ground. Set
EXT SIF switch to-
a. Meter indicates zero ohm.
a. Check switch 1A1A1S8 and
a. ON
associated wiring.
b. Meter indicates open circuit .
b. Check switch 1A1A1S7 and
b. OFF
associated wiring.
7
1A1A1J10-J and ground. Set
EXT M4 switch to--
a. Meter indicates zero ohm.
a. Check switch 1A1A1S8 and
a. ON
associated wiring.
b. Meter indicates open circuit.
b. Check switch 1A1A1S8 and
b. OFF
associated wiring.
8
1A1A1J10-D and ground. Set
SIF TAIL. switch to--
a. Meter indicates zero ohm .
a. Check switch 1A1A1S9 and
a. ON
associated wiring.
b. Meter indicates open circuit.
b. Check switch 1A1A1S9 and
b. OFF
associated wiring.
9
1A1A1J10-K and ground. Set
EXT MODE C switch to--
a. Meter indicates zero ohm.
a. ON
a. Check switch 1A1A1S10 and
associated wiring.
b. Meter indicates open circuit.
b. OFF
b. Check switch 1A1A1S10 and
associated wiring.
10
1A1A1J10-j and ground. Set
EXT TEST TGT switch to--
a. Meter indicates zero ohm.
a. ON
a. Check switch 1A1A1S11 and
associated wiring.
b. Meter indicates open circuit.
b. OFF
b. Check switch 1A1A1S11 and
associated wiring.
11
1A1A1J10-g and ground. Set
TRIG CONTROL switch to--
a. Meter indicates zero ohm.
a. ON
a. Check switch 1A1A1S12 and
associated wiring.
b. Meter indicates open circuit.
b. OFF
b. Check switch 1A1A1S12 and
associated wiring.
12
1A1A1J10-h and ground. Set
INHIBIT GATE switch to--
a. Meter indicates zero ohm
a. ON
a. switch 1A1A1S13 and associated
wiring.
b. Meter indicates open circuit.
b. OFF
b. Switch 1A1A1S131 and associated
wiring
4-5