TM 11-6625-2398-15-2
Step
Test equipment
Equipment under test
No.
control settings
control settings
Test procedure
Performance standard
16
..............................................
Set POWER 400 HzRepeat step 12.
switch to OFF.
17
..............................................
Set POWER 400-Hz
Same as step 13.
switch to ON>
Insert extender pins (para 6-2e)
18
..............................................
Set POWER 400-Hz
a.
switch to OFF.
over 1A1A1J10-P and -R.
b.
1A1A1J10-P and -R.
19
..............................................
............................................
a.
Set AZIMUTH DATA SYNC
/RSLVER SEL switch to
smoothly from 0 to 28 v-p-p
minimum, to 73 v-p-p 23 v-p-p
RSLVR and AZIMUTH DATA
FREQ SELECT switch to 4000
maximum, at 4 kHz.
HZ.
b.
Set POWER 400-Hz switch to
b.
None.
ON.
Insert extender pins (para 6-2e)
None.
20
..............................................
Set Power 400-Hz
a.
switch to OFF.
over 1A1A1J10-T and -U.
b.
Connect oscilloscope to
1A1A1J10-T and -U.
21
..............................................
Set POWER 400-Hz
..........................................
Same as step 19 above.
switch to ON.
22
..............................................
Set GROUP CASE
POWER 60-Hz and
400-Hz switches to
OFF. Set GROUP
CASE POWER
SELECT switch to
OFF. Set POWER 60-
Hz and 400-Hz
switches to OFF.
23
TS-352 B/U FUNC-
EXT SIF: OFF.
a.
into OHMS DCAC jack.
TION: OHMS
EXT M4: OFF
RANGE switch:
SIF TAIL: OFF.
b.
RX10.
EXT MODE C: OFF.
OHMS jack.
EXT TEST TGT:
OFF.
TRIG CONTROL:
OFF.
INHIBIT GATE OFF.
24
..............................................
............................................
a.
Connect multimeter to
a.
Infinity.
1A1A1J10-C and -H.
b.
Set EXT SIF switch to ON>
b.
Less than 1 ohm.
25
..............................................
............................................
a.
Connect multimeter to
a.
Infinity.
1A1A1J10-C and -J.
b.
Set EXT M4 switch to ON.
b.
Less than 1 ohm.