TM 11-6625-2398-15-2
Step
Test equipment
Equipment under test
No.
control settings
control settings
Test procedure
Performance standard
a.
a.
33
------------------------------------------------------------------------------
Connect multimeter to S1 test point TP9 and
Less than 1 ohm.
1A1A1J10-c.
b. Connect multimeter to S2 test point TP10 and
b.
Less than 1 ohm.
1A1A1J10-d.
c. Connect multimeter to S3 test point TP11 and
o.
Less than 1 ohm.
1A1A1J10-e.
d. Connect multimeter to R1 test point TP12 and
d.
Less than 1 ohm.
1A1A1J10-Z.
e. Connect multimeter to R2 test point TP13 and
e.
Less than 1 ohm.
1A1A1J10-a.
a. Connect multimeter to CMPTR TGT START test
a.
Infinity.
34
------------------------------------------------------------------------------
point TP1 and ground.
b. Connect multimeter to CMPTR TGT END test
b.
Infinity.
point TP2 and ground.
c. Connect multimeter to CMPTR TGT PRESENT
c.
Infinity.
test point TP3 and ground.
d. Connect multimeter to CMPTR TRUE FRND
d.
Infinity.
test point TP4 and ground.
e. Connect multimeter to UNDECODED MODE C VID
e.
Infinity.
test point TP5 and ground.
f.
Infinity.
point TP6 and ground.
g. Connect multimeter to IFF DISPLAY VID test
g.
Infinity.
point TP7 and ground.
h. Connect multimeter to BUFFERED RCVR VID test
h.
Infinity.
point TP8 and ground.
i. Connect multimeter to S1 test point TP9 and ground
i.
Infinity.
j. Connect multimeter to S2 test point TP10O and
j.
Infinity.
ground.
k. Connect multimeter to S3 test point TP11 and
k.
Infinity.
ground.
I. Connect multimeter to R1 test point TP12 and
1.
Infinity.
ground.
m. Connect multimeter to R2 test point TP13 and
m. Infinity.
ground.
Change 1 8-9