TM 11-6625-2398-15-3
centered on the back of the shell). Slip out the clips.
for the uncalibrated cable and connect the test
Bend cable W39 into a circle and insert male connector
P1 into female connector P2.
(10) Repeat steps (7) and (8) for the uncalibrated
(2) Repeat steps (1) through (8) of b above,
W14/W15 cable.
substituting plugs P3 and P4 of W39 (sleeve markings
P1/A-P2/A) as the cable to be tested in step b(4).
(11) Reconnect the test equipment as shown with
Insertion loss of cable at both frequencies must not
solid lines in figure 6-6 and set the MEGA- CYCLES dial
exceed 2.0dB.
(3) Repeat steps (3) through (8) of b above,
(12) Repeat steps (3) through (6) above.
substituting plugs P5 and P6 of W39 (sleeve markings
P1/A-P2/A) as the cable to be tested in step b(4).
Insertion loss of cable at both frequencies must not
exceed 2.0dB.
(1) Remove and retain couplers CP1 and CP2.
Remove the retaining clips on one end of the cable by
(4) Remove cable W39 from the test set-up,
loosening six screws on the shell (four cornered on the
disengage plugs P2 and P1, replace the two retaining
mating side and two
clips and tighten the six loosened screws. Replace
couplers CP1 and CP2 between plugs P3/P4 and P5/P6,
respectively.
6-16