Home
Download PDF
Order CD-ROM
Order in Print
Home
>
Test Facility Manuals and other related material
>
> TM-11-6625-2398-15-3 Test Facilites Set AN/TPM-24(V)3 (NSN 6625-00-133-7865) Manual
Figure 1-1. Test Facilities Set AN/TPM-24(V)3
Chapter 1. INTRODUCTION - TM-11-6625-2398-15-30005
Technical Characteristics - TM-11-6625-2398-15-30006
Common Names - TM-11-6625-2398-15-30007
Description of Major Components - TM-11-6625-2398-15-30008
Figure 1-2. Case, Test Facilities Set CY-6825/TPM-24(v) 3
Figure 1-3. Hybrid Attenuator Assembly CN-1322/TPM-24(V).
Figure 1-4. Adapter. Test MX-8565/ TPM-24(V).
Figure 1-5(1) Test Facilities Set AN/TPM-24fV)t. cable assemblies (part 1 of 2).
Figure 1-5(1) Test Facilities Set AN/TPM-24fV)t. cable assemblies (part 2 of 2).
Figure 1-6(1) Test Facilities Set AN/TPM-24(V)3, minor components (part 1 of 2).
Figure 1-6(1) Test Facilities Set AN/TPM-24(V)3, minor components (part 2 of 2).
Chapter 2. INSTALLATION - TM-11-6625-2398-15-30016
Figure 2-1. Packaging of Test Facilities Set AN/TPM-24(V)3.
Figure 2-1. Packaging of Test Facilities Set AN/TPM-24(V)3. (cont)
Chapter 3. OPERATING INSTRUCTIONS - TM-11-6625-2398-15-30019
Figure 3-1. Hybrid attenuator A1, operating control, connectors and cable.
Section II. OPERATION - TM-11-6625-2398-15-30021
Connection of Input Power and Adapter Cables
Figure 3-3. Connections of test cables to the IFF set.
Operation of Hybrid Attenuator
Figure 3-4. Typical hybrid attenuator receiver and transmitter test connections.
Chapter 4. OPERATOR'S AND ORGANIZATIONAL MAINTENANCE - TM-11-6625-2398-15-30026
Preventive Maintenance Checks and Services Periods
Cleaning - TM-11-6625-2398-15-30028
Continuity Check of Cables, Extender Boards, and Front Panel Test Adapter
Extender Board A5
Figure 4-1. Multimeter test connections.
Chapter 5. FUNCTIONING - TM-11-6625-2398-15-30032
Cable W13
Chapter 6. GENERAL SUPPORT MAINTENANCE - TM-11-6625-2398-15-30034
Section II. COMPONENT TROUBLESHOOTING
Section III. COMPONENT TESTING AND CALIBRATION
Power Cable W32
Cable W43
Figure 6-1. Cable megger test connections.
Hybrid Attenuator Difference Channel (RF IN/OUT to ATTEN IN/RF DIFF Jacks) Insertion Loss Calibration
Figure 6-2. Hybrid attenuator sum channel (RF IN/OUT to RF SUM jacks) insertion loss, calibration conclusions.
Procedure.
Figure 6-3. Hybrid attenuator difference channel (RF IN/OUT to ATTEN IN/RF DIFF jacks) insertion loss, calibration connections.
Hybrid Attenuator ATTENUATOR Dial Calibration
Hybrid Attenuator VSWR Measurements - TM-11-6625-2398-15-30045
Figure 6-4. Hybrid attenuator ATTENUATOR dial, calibration connections.
Calibration of Insertion loss for Cables W14/W11 and W39
Figure 6-5. Hybrid attentuator VSWR, test connections
Procedure for Cable W39
Figure 6-6. RF cable insertion losses, calibration connections.
Figure 6-10. Cable W32, schematic diagram.
Figure 6-12. Cable W40, schematic diagram.
Figure 6-14. Cable W42, schematic diagram.
Figure 6-15. Cable W43, schematic diagram.
Figure 6-18. Cable W48, schematic diagram.
Figure 6-19. Hybrid Attenuator Assembly CN-1322/TPM-24(V), schematic diagram.
Figure 6-20. Adapter, Test MX-8565/TPM-24(V), schematic diagram.
Figure 6-21. Extender board A3/A4, schematic diagram.
Figure 6-22. Extender board A5, schematic diagram.
Figure 6-23. Cable W21, schematic diagram.
Chapter 7. REPAIRS
Figure 7-1. Part locations, hybrid attenuator A1.
Cable W16
Cable W21
Cable W39
Cable W48
Cable A1W3
Cable to A2P1
Figure 7-2. Cable stripping details.
Figure 7-3. Assembly of connectors on cables W16, W45 and W47, and portions of hybrid attenuator cables.
Figure 7-4. Assembly of alligator clips on cable W16.
Figure 7-5. Assembly of connectors on cables W14/W15, W39, W45, W47, and hybrid attenuator cables.
Figure 7-6. Assembly of connectors on cable W48 and portions of hybrid attenuator cables.
Figure 7-7. Assembly of connector W21P2.
Figure 7-8. Assembly of connector W21P1.
Chapter 8. GENERAL SUPPORT TESTING PROCEDURES - TM-11-6625-2398-15-30076
Modification Work Orders - TM-11-6625-2398-15-30077
Figure 8-1. Cables, front panel test adapter and extender boards, continuity test conditions.
Continuity Tests on Cables, Extender Boards and Front Panel Test Adapter
Insulation Resistance Tests on Cables
Figure 8-2. Cable insulation resistance, test conditions.
Insulation Resistance Tests on Cables (cont) - TM-11-6625-2398-15-30082
Insulation Resistance Tests on Cables (cont) - TM-11-6625-2398-15-30083
Insulation Resistance Tests on Cables (cont) - TM-11-6625-2398-15-30084
Hybrid Attenuator Insertion Loss Measurement between RF IN/OUT and RF SUM Connectors
Figure 8-3. Hybrid attenuator sum channel (between RF IN/OUT and RF SUM connectors) insertion loss, test connections.
Hybrid Attenuator Insertion Loss Measurement between RF IN/OUT and RF SUM Connectors (cont)
Figure 8-4. Hybrid Attenuator difference channel (between RF IN/OUT and ATTEN IN/RF DIFF connectors) insertion loss, test connections.
Hybrid Attenuator Insertion Loss Measurement between RF IN/OUT and ATTEN IN/RF DIFF Connectors
Hybrid Attenuator Insertion Loss Measurement between RF IN/OUT and ATTEN IN/RF DIFF Connectors (cont)
Hybrid Attenuator Calibration Tests - TM-11-6625-2398-15-30091
Figure 8-5. Hybrid attenuator calibration, test connections.
Hybrid Attenuator Calibration Tests - TM-11-6625-2398-15-30093
Hybrid Attenuator VSWR Measurements - TM-11-6625-2398-15-30094
Figure 8-6. Hybrid Attenuator VSWR, test connections.
Hybrid Attenuator VSWR Measurements (cont)
Insertion loss measurements for Cables W14/W15 and W39
Insertion loss measurements for Cables W14/W15 and W39 (cont)
Test Data Summary
Chapter 9. DEPOT OVERHAUL STANDARDS - TM-11-6625-2398-15-30100
Insertion losses
Chapter 10. SHIPMENT AND LIMITED STORAGE, AND DEMOLITION TO PREVENT ENEMY USE
Section II. DEMOLITION OF MATERIAL TO PREVENT ENEMY USE
Appendix A. REFERENCES - TM-11-6625-2398-15-30104
Appendix C. MAINTENANCE ALLOCATION - TM-11-6625-2398-15-30105
Tool and Test Equipment Requirements (Sec III) - TM-11-6625-2398-15-30106
SECTION II MAINTENANCE ALLOCATION CHART FOR TEST FACILITIES SET AN/TPM-24(V)3
SECTION II MAINTENANCE ALLOCATION CHART FOR TEST FACILITIES SET AN/TPM-24(V)3 (cont)
SECTION III TOOL AND TEST EQUIPMENT REQUIREMENT FOR TEST FACILITIES SET AN/TPM-24(V)3
SECTION IV. REMARKS - TM-11-6625-2398-15-30110
Appendix D. ORGANIZATIONAL, DIRECT SUPPORT, GENERAL SUPPORT, AND DEPOT MAINTENANCE REPAIR PARTS AND SPECIAL TOOLS LIST
Maintenance code.
Location of Repair Parts
SECTION II REPAIR PARTS FOR ORGANIZATIONAL MAINTENANCE
SECTION II REPAIR PARTS FOR ORGANIZATIONAL MAINTENANCE (cont)
SECTION III REPAIR PARTS FOR DIRECT SUPPORT, GENERAL SUPPORT, AND DEPOT MAINTENANCE
SECTION III REPAIR PARTS FOR DIRECT SUPPORT, GENERAL SUPPORT, AND DEPOT MAINTENANCE (CONTINUED) - TM-11-6625-2398-15-30117
SECTION III REPAIR PARTS FOR DIRECT SUPPORT, GENERAL SUPPORT, AND DEPOT MAINTENANCE (CONTINUED) - TM-11-6625-2398-15-30118
SECTION III REPAIR PARTS FOR DIRECT SUPPORT, GENERAL SUPPORT, AND DEPOT MAINTENANCE (CONTINUED) - TM-11-6625-2398-15-30119
SECTION III REPAIR PARTS FOR DIRECT SUPPORT, GENERAL SUPPORT, AND DEPOT MAINTENANCE (CONTINUED) - TM-11-6625-2398-15-30120
SECTION III REPAIR PARTS FOR DIRECT SUPPORT, GENERAL SUPPORT, AND DEPOT MAINTENANCE (CONTINUED) - TM-11-6625-2398-15-30121
SECTION III REPAIR PARTS FOR DIRECT SUPPORT, GENERAL SUPPORT, AND DEPOT MAINTENANCE (CONTINUED) - TM-11-6625-2398-15-30122
SECTION III REPAIR PARTS FOR DIRECT SUPPORT, GENERAL SUPPORT, AND DEPOT MAINTENANCE (CONTINUED) - TM-11-6625-2398-15-30123
SECTION III REPAIR PARTS FOR DIRECT SUPPORT, GENERAL SUPPORT, AND DEPOT MAINTENANCE (CONTINUED) - TM-11-6625-2398-15-30124
SECTION III REPAIR PARTS FOR DIRECT SUPPORT, GENERAL SUPPORT, AND DEPOT MAINTENANCE (CONTINUED) - TM-11-6625-2398-15-30125
SECTION III REPAIR PARTS FOR DIRECT SUPPORT, GENERAL SUPPORT, AND DEPOT MAINTENANCE (CONTINUED) - TM-11-6625-2398-15-30126
SECTION IV REPAIR PARTS FOR DIRECT SUPPORT, GENERAL SUPPORT, AND DEPOT MAINTENANCE
SECTION V INDEX-FEDERAL STOCK NUMBER AND REFERENCE NUMBER CROSS REFERENCE TO FIGURE AND, ITEM NUMBER OR REFERENCE DESIGNATION
SECTION V INDEX-FEDERAL STOCK NUMBER AND REFERENCE NUMBER CROSS REFERENCE TO FIGURE AND, ITEM NUMBER OR REFERENCE DESIGNATION (cont) - TM-11-6625-2398-15-30129
SECTION V INDEX-FEDERAL STOCK NUMBER AND REFERENCE NUMBER CROSS REFERENCE TO FIGURE AND, ITEM NUMBER OR REFERENCE DESIGNATION (cont) - TM-11-6625-2398-15-30130
SECTION V INDEX-FEDERAL STOCK NUMBER AND REFERENCE NUMBER CROSS REFERENCE TO FIGURE AND, ITEM NUMBER OR REFERENCE DESIGNATION (cont) - TM-11-6625-2398-15-30131
SECTION VI INDEX- REFERENCE DESIGNATION CROSS REFERENCE TO PAGE NUMBER
SECTION VI INDEX- REFERENCE DESIGNATION CROSS REFERENCE TO PAGE NUMBER (cont)
TM-11-6625-2398-15-3 Test Facilites Set AN/TPM-24(V)3 (NSN
6625-00-133-7865
) Manual
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business