TM 11-6625-2398-15-3
measure the hybrid attenuator VSWR (para 6-11).
(g) Insert cable and contact-wedge
l. Cable A1W3. If any part of the cable assembly
assembly into body assembly. Tighten nut securely to
complete assembly.
is damaged, the entire assembly must be rebuilt. Use a
new six inch length of RG-58C/U, and new or salvaged
connectors.
and measure the hybrid attenuator VSWR (para 6-11).
(1) Attach connectors P1 and P2 to the new
n. Cable to A1J4 (fig. 7-1). If
any part of
the cable
cable by repeating steps b(2) through b(7).
assembly is damaged, the entire assembly must be
rebuilt. Use a new eight inch length of RG-58C/U and
new or salvaged connectors.
and measure the hybrid attenuator VSWR (para 6-11).
(1) To attach connectors A1J4, repeat steps
m. Cable to A1J1 (fig. 7-1). If
any part of
the cable
b(2) through b(7).
assembly is damaged, the entire assembly must be
rebuilt. Use a new eight inch length of RG-58C/U, and
(2) The procedure for attaching A1P2 is as
new or salvaged connectors.
follows:
(1) To attach connector A1J1, repeat steps
(a) Repeat steps b(2) through b(5).
b(2) through b(7).
(b) Insert cable into angle body. Make
(2) To attach connector A1P1, proceed as
sure that inner conductor is nested into slot of contact,
follows:
and knife edge of braid clamp is properly seated in V-
(a) Slip nut assembly over cable (A, fig.
groove gasket. Tighten clamp nut securely.
(c) Solder inner conductor to contact
(b) Cut off 1/2 inch of jacket and braid
through opening in body.
from the end of the cable (dimension (A), B, fig. 7-2).
(d) Place cover in position and screw
Do not damage the cable dielectric.
into place to complete assembly.
(c) Cut off dielectric (dimension (B), B,
fig. 7-2) from jacket and braid. Do
not nick the inner
and measure the hybrid attenuator VSWR (para 6-11).
conductor.
o. Cable to A1J5 (fig. 7-1). If
any part of
the cable
assembly is damaged, the entire assembly must be
rebuilt. Use a new eight inch length of RG-58C/U and
(e) Cut 3 slits 1/8 inch long and 120
new or salvaged connectors.
degrees apart in outer jacket only (C, fig. 7-6) without
disturbing braid. Raise outer jacket and braid away from
(1) To attach connector A1J5, repeat steps
dielectric in order to facilitate the entry of contact-wedge
b(2) through b(7).
assembly. Straighten inner conductor if necessary.
(2) To attach connector A1P3 to the cable,
(f) Slide
contact-wedge
assembly
repeat steps 1(2)(a) through 1(2)(g).
under braid and jacket (D, fig. 7-6). Push back as far as
possible, making sure that inner conductor is visible
and measure the hybrid attenuator VSWR (para 6-11).
through side hole of contact. Solder contact to inner
p. Cable to A2P1. If the conductors of the cable
conductor through side hole and make sure outside
are damaged beyond repair, rebuild the cable assembly
surfaces are free of solder. Avoid used of excessive
heat.
connections. Salvage
7-7