TM 11-6625-2398-14-4
Figure 7-3. Stripping Details, Cables 1A1 W3 and W4 and W6 through WIO.
(3) Place tag marker over outside of cable
(8) Bend braid back over clamp and trim
excess braid. Make sure braid does not extend past
jacket.
(4) Strip 7/32 inch of insulation from both
(5) Obtain new connector or salvage
view E).
connector from defective cable assembly. Disassemble
(10) Solder contact to center conductor making
sure outside surfaces are free of solder. Avoid use of
(6) Slip clamp nut, washer, and gasket over
excessive heat. Contact should be flush against cable
(7) Comb out braid smoothly and taper over
dielectric. Slide braid clamp over braid and push back
7-4