TM 11-6625-1683-15
(7) Replace epoxy material; maintain di-
b. To replace rubber covered wire, proceed
mensions noted in (1) above.
as follows:
(1) Strip each end one-eighth inch and
b. Female Connector. Replace connector by
tin.
using the procedure given in a(1) through
(2) Assemble to fittings as outlined in
(7) above.
a(l) through (6) above.
c. Cable. Replace cable as follows:
(1) Remove connectors from cable as out-
7-22. Electrical Lead CX-10448/PPS5
lined in a(l), (2), and (3) above.
(2) Connect conductors of replacement
cable to connectors as outlined in a(4)
through (7) above.
7-23. Special Purpose Electrical Cable
7-24. Special Purpose Branched Electrical
Assembly CX-10440/PPS-5
Cable Assembly CX-10441/PPS-5
a. Male Connector. Replace connector as
a. Male Connector. Replace connector as
follows:
follows:
(1) Note dimensions of epoxy material.
(1) Note relationship of connectors to
(2) Remove epoxy material and rubber
plate; disassemble index plate assem-
bly.
nector contacts.
(2) Note dimensions of epoxy material;
(3) Unsolder cable conductors from con-
remove epoxy material from connec-
tacts of connector.
t o r s . (Salvage threaded inserts in
(4) On replacement connector, remove
epoxy.)
and discard contacts J, L, M, N, R,
(3) U n s o l d e r cable conductors from
and V.
printed-circuit boards.
(5) Solder cable conductors to replace-
(4) Solder replacement connectors to re-
ment connector.
placement printed-circuit boards.
terial around connector terminals.
(5) Solder cable conductors to boards.
Figure 7-23. Electrical Lead CX-10452/PPS-5, schematic diagram.
Figure 7-24. Electrical Lead CX-10448/PPS-5, schematic diagram.t
AGO 7918A
7-21